Technical Data

Level weighbridge with multi-part base

The standard level bridges are available in the one-piece model in lengths of 8.00 m; 9.00 m; 10.00 m and in the two-piece model in lengths of 16.00 m; 18.00 m and 20.00 m. Longer models can also be constructed as a three piece implementation.

Level scale bridge length [m]Number of load cellsScale bridge classOuter dimensions [m]Height[m]Width [m]Weight [t]
8,004508,440,803,3430,90
9,004509,440,803,3434,40
10,0046010,440,953,3441,70
16,0086016,440,803,3459,00
18,0086018,440,803,3466,10
20,0086020,440,953,3480,10

  • 8 load cells are needed for the two-piece bridge and 4 load cells for the one-piece bridge.
  • Each bridge is provided with 2 access openings with round covers for maintenance and cleaning.
  • The level scales can be passed over from all sides.
  • For the wiring, DN 40 ductworks are provided under the bridge reflector.
  • Edge protection profiles 60/60/6 from ST 37 are provided at both ends as well as 0.75 m along the longitudinal side.
  • There are bumper bags with M 20 screws and washers for these are built into the edge protection profile.
  • Bearing plates provided for placing in the load cells.
  • The textured, nubbed bridge surfaces provide non-slip security.
  • The closed prefabricated foundation cavities can be constructed in outer lengths of 8.44 m; 9.44 m; 10.44 m in the one-piece model, and in lengths of 16.44 m; 18.44 m and 20.44 m in the two-piece model.
  • The foundations are constructed "overhead" in order to deliver an optimal look in exposed concrete.
  • Two DN 100 pipes are provided at both ends for draining the foundations and two DN 100 pipes on the longitudinal side are provided for wiring.
  • Connections for lightning protection are provided.

Within a few hours these level scales can be mounted on a strip foundation according to building plan.

 

The advantages of this system:

  • Limited excavation required
  • Simple gauging of a statically definite system
  • High flexibility - the scales can be relocated (incl foundations)
  • Inner cable ducts
  • High resistance to wear
  • Watertight implementation according to WHG also possible
  • Anti-slip structured surface
  • May be provided with protective panelling
  • Cavities can be created with integrally formed foundations
  • Small crane for assembly
  • Scales may also be provided with pile foundations

 